Out For Tender › Estados Unidos › Trabajos de construcción
Electric Power Resiliency Building 56
- Órgano de contratación
- DLA DISTRIBUTION, Dept of Defense
- País
- Estados Unidos
- Categoría
- Trabajos de construcción
- Fecha límite
- Cierra en 21 días (9 Dec 2026 13:00 UTC-5)
- Publicada
- 13 Nov 2026
- Procedimiento
- Combined Synopsis/Solicitation - Small Business Set Aside - Total
Leer el anuncio oficial y licitar → La presentación de ofertas se realiza siempre en el portal del órgano de contratación, nunca aquí.
Qué solicita el órgano de contratación
Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.
Idioma de este anuncio: English. El título y la descripción se muestran tal como los publicó el órgano de contratación.
How this compares
- This is one of 982 open tenders in Estados Unidos for Trabajos de construcción.
- Bidders were given 26 days from publication to the deadline; the median for open tenders in Estados Unidos is 17 days.
More open tenders from this buyer
DDRV DOT Ozone Inspection
DLA DISTRIBUTION, Dept of Defense
Cross Connection Hazard Assessment
DLA DISTRIBUTION, Dept of Defense
Electric Power Resiliency Building 56
DLA DISTRIBUTION, Dept of Defense
Electric Power Resiliency Building 56
DLA DISTRIBUTION, Dept of Defense
Electric Power Resiliency Building 56
DLA DISTRIBUTION, Dept of Defense
Similar open tenders
91st Cyber Operations Center Progressive Design-Build Other Transaction Agreement
W076 ENDIST FT WORTH, Dept of Defense
Y--GRCA 257282 - Replace Wastewater Plant at South Ri
DSC CONTRACTING SERVICES DIVISION, Interior, Department of the
91st Cyber Operations Center Progressive Design-Build Other Transaction Agreement
W076 ENDIST FT WORTH, Dept of Defense
91st Cyber Operations Center Progressive Design-Build Other Transaction Agreement
W076 ENDIST FT WORTH, Dept of Defense
91st Cyber Operations Center Progressive Design-Build Other Transaction Agreement
W076 ENDIST FT WORTH, Dept of Defense
Source: SAM · reference SP330027Q0012 · JSON